What was found
CORROSION ON STRINGER 20R BETWEEN FS581.00 AND FS597. REMOVED AND INSTALLED NEW STR20R BETWEEN BS 581 AND 597 IAW REO 690-53-31-1095 REV --A, DWG SH690-33302, REV C, SRM 51-42-21-001-001-A01, SRM 53-00-03-201-001-A02, AND SRM 51-42-06-001-001-A01. COMPLIED WITH TALL STEPS OF REO 690-53-31-1095 REV A. COMPLIED WITH TASK CARD 51-900-1002-SKY.