AFTER EDDY CURRENT INSPECTION OF THE WINDWSHIELD CENTER POST , NR 8 ATTACH STRUCTURE CRACKS WERE FOUND IN LOWER PART. R & R WINDWSHIELD CENTER POST NR 8 ATTACH STRUCTURE IAW 00 SRM 51-24-16, SRM 51-42-21, IPC 53-11-19, PAGE 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER EDDY CURRENT INSPECTION OF THE WINDWSHIELD CENTER POST , NR 8 ATTACH STRUCTURE CRACKS WERE FOUND IN LOWER PART. R & R WINDWSHIELD CENTER POST NR 8 ATTACH STRUCTURE IAW 00 SRM 51-24-16, SRM 51-42-21, IPC 53-11-19, PAGE 6.