What was found
FOUND EVIDENCE OF CORROSION ON STRINGER SPLICE 21L, BS 333. REMOVED THE STRINGER SPLICE, BS 333 IAW SRM 51-42-06-001-001-A01, REV OA. INSTALLED THE STRINGER SPLICE IAW SRM 51-42-06-001-001-A01, REV OA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.