What was found
COMPLY WITH PERMANENT REPAIR OF LT WING OTBD GROUND SPOILER, INBD HINGE FITTING ON AUX SPAR, DAMAGE AROUND BONDING STRAP ATTACHMENT. REPAIRED THE LT WING OTBD GROUND SPOILER INBD HINGE FITTING ON AUX SPAR AROUND BONDING STRAP ATTACHMENT IAW REO 601R-57-51-951, REV-. REPAIR ACCEPTABLE FOR 6000 FLT HRS FROM THE TIME OF INCORP OF REO. REMOVED & REPLACED THE DAMAGED LT WING INBD GROUND SPOILER HINGE FITTING WITH A NEW GROUND SPOILER HINGE FITTING USING ALL NEW FASTENERS PER DWG 601R10032 REV -U, DWG 601R10333 REV D, AND SRM 51-42-06 AND 51-42-21.