What was found
1 DENT LOCATED APRROXIMATELY 6" AFT OF FS 654.50 BETWEEN STRINGERS 22L AND 23L. (C-CHECK RO 12/19/2025)COMPLIED WITH REO 601R-53-61-8393 REV "--" DATED 2025-10-16. REPAIR FOR DENT AND GOUGE DAMAGE TO FUSELAGE SKIN BETWEEN FS654.50 - FS672.20 AND STR21L - STR23L PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1, 51-20-06, NDTM PART 6, 53-00-096, AND PERFORMED HOLE EDDY CURRENT ROTARY PROBE INSPECTION WITH REFERENCE TO NDTM PART 6, 53-00-097 WITH NO DEFECT FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLETED M-337.