What was found
CORROSION BEYOND ALLOWABLE LIMITS AT FS589 BETWEEN STR26L-26R REMOVED RIVETS AS NEEDED AT FS 589.00 FROM STR26L- STR26R IAW SRM 51-42-06. BLENDED CORROSION AT FS 589.00 FROM STR26L- STR26R IAW SRM 51-21-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT IAW NDTM PART 4, 51-00-001 AND FOUND TO BE WITHIN ACCEPTABLE LIMITS OF REO 601R-53-61-8389 REV--. PERFORMED AN EDDY CURRENT INSPECTION OF THE BLENDED AREA IAW NDTM PART1, 51-20-06 AND NDTM PART 6, 53-00-096. INSTALLED RIVETS AS NEEDED IAW SRM 51-42-06. RESTORED SURFACE FINISH AND APPLIED CIC IAW SRM 51-21-16 AND SRM 51-21-11.