As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR BOARD SUPPORT STRAP AT APPROX. FS.559.00 BETWEEN RBL9 AND RBL36 HAS MULTIPLE SPOTS OF CORROSION (MARKED). REPLACED FLOORBOARD SUPPORT STRAP AT FS.559.00 BETWEEN RBL9 AND RBL36 REF. DWG 601R31025 REV. N, CRJ200 SRM 51-42-06-00, AND CRJ200 SRM 51-42-15-00. LEAK CHECK GOOD.COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY