What was found
MULTIPLE CORRODED FASTENERS UNDER PANEL 196AL, 192BB AND 191BB. (C-CHECK RO 09/24/2025)REPAIRED COROSION ON SKIN AND FASTENERS UNDER PANEL LANDINGS 196AL, 192BB, AND 191BB REF CRJ200 SRM 51-21-06. COMPLIED WITH STEPS 1-4 OF REO 601R-53-00-916 REV -- DATED 2025-08-19. FOUND TO BE WITHIN LIMITS REF REO 601R-53-00-916 REV -- DATED 2025-08-19. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY AND FORM 337.