What was found
2EA FASTENER HOLES WITH NOTED CORROSION ON THE HORIZONTAL STABILIZER, UNDER ACCESS PANEL 333AL (MARKED). (C-CHECK RO 01/03/2026)REMOVED CORROSION ON 2EA FASTENER HOLES ON THE HORIZONTAL STABILIZER, UNDER ACCESS PANEL 333AL. REF 601R-55-11-812 REV. --, DATED: 2025-11-24. STEPS 3-5. REMAINING REO STEPS COMPLIED WITH ON CAMP # 31014392. SEE CONTINUATION CARD FOR DETAILS. M-337 AND SKYWEST TASK CARD 51-900-1003-SKY COMPLIED WITH.