Service difficulty report · Overheat Loop · Cndair CL6002C10

Difficulty date
January 13, 2026
Submitted
January 20, 2026
Operation
Air carrier
Aircraft
N794SK
Make and model
Cndair CL6002C10
Aircraft serial
10298
Aircraft time
38,326 hours, 25,225 cycles
Part
Overheat Loop
Condition
Faulted
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ANTI ICE DUCT WARNING ON CLIMB OUT OF DEN. QHR CLEARED THE MSG AND WE DIDN€™T NEED TO USE THE ANTI ICE AFTER THAT. (FLIGHT 5366) INTERROGATED MDC AND FOUND B1 CODES 007309 (L WING LOOP B) AND 007180 (L BLEED LOOP A). TROUBLESHOT L BLEED LOOP A PER FIM 36-21-01-810-801. USING BREAKOUT BOX TESTED RESISTANCE TO L BLEED LOOP A AND RECORDED RESISTANCE SLIGHTLY HIGHER THAN NOMINAL VALUE BUT NOT TWICE NOMINAL VALUE. TAPPED ON ALL ASSOCIATED CONNECTIONS AND MOVED BLEED LOOPS AROUND IN ORDER TO TRY TO SEE A JUMP IN VALUES. NO JUMP IN RESISTANCE VALUES NOTED AT THIS TIME. HOWEVER, DURING INSPECTION OF CONNECTIONS NOTICED THAT CONNECTOR MT137 APPEARED EXCESSIVELY BACKED OFF AND ONCE SAFETY CABLE WAS CUT COULD BE LOOSENED BY HAND. CLEANED CONNECTION AND REPLACED CERAMIC INSERT AT CONNECTION POINT MT137 PER AMM 36-21-00 AND RECONNECTED AND PROPERLY TORQUED CONNECTION PER AMM 36-21-00. UPON INITIAL ARRIVAL TO AC DUCT MON FAULT WAS POSTED HARD FAULTED. UPON POWERING UP AC AFTER WORK WAS ACCOMPLISHED, DUCT MON FAULT MESSAGE NO LONGER POSTED. PER