What was found
CORROSION ON FLOOR SUPORT AT RBL 9 BETWEEN BS 409.5 AND BS 409 + 32 FOUND TO BE OUT OF LIMITS. PERFORMED REPAIR OF THE FLOOR SUPPORT IAW SRM 53-00-43 & REO 601R-53-31-1366 REV--. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1, 51-20-06 AND NDTM PART 6 53-00-096 WITH NO DEFECTS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY.