What was found
RIGHT PRESSURE FLOOR SILL HAS MULTIPLE AREAS OF CORROSION DAMAGE BETWEEN FS409.00+112 TO FS559.00 AND BETWEEN RBL 36.0 TO RBL 45.0. BLENDED MULTIPLE AREAS OF CORROSION DAMAGE ON RT PRESSURE FLOOR SILL BETWEEN BS 409+112 TO 559, BETWEEN RBL 36 TO RBL 45 IAW SRM 51-21-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT IAW NDTM PART 4 51-00-001 & FOUND TO BE ACCEPTABLE PER REO 601R-53-41-666 REV-. PERFORMED EDDY CURRENT INSPECTION IAW NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. RESTORED SURFACE FINISH IAW SRM 51-21-16. COMPLIED WITH TASK CARD 51-900-1003-SKY.