What was found
PAX DOOR CUTOUT FRAME FS310 FITTING CAM CHAFED AFTER CLEANED AREA FOUND CORROSION ON CHAFFED AREA, NO ALLOW. LIMIT FOUND ON SRM. REQ. REPLACEMENT. ORDER NEW FITTING CAM FS310.00 P/N 600-31688-17. PERFORMED LOCATE AND DRILL NEW PAX DOOR FS310 FITTING CAM. IAW SRM 51-42-21-00 AND DWG 600-31900 REV. K. INSTALLED NEW FITTING CAM FS310 IAW SRM 51-42-21 AND DWG NO 600-31900 REV K, COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY