What was found
BS 280 FORWARD FLOORBEAM ANGLE, REF DWG 600-34017, SRM 53-11-19, BETWEEN RBL 9.0 AND LBL 9.0 CRACKED. REMOVED AND REPLACED THE BS 280 FORWARD FLOORBEAM ANGLE, RBL 9 AND LBL 9 IAW SRM 51-42-06, & SRM 51-42-21. COMPLIED WITH TASK CARD 51-900-1003-SKY. . REF 31838587 FOR THE COMPLETION OF REO REO 601R-53-11-4061 AND REO 601R-53-11-926B.