What was found
FOUND MULTIPLE SPOTS OF SURFACE CORROSION ON RT PRESSURE FLOOR SILL FROM FS 409.00+128 AND FS 559.00 FROM RBL 36.00 TO RBL 45.00. BLENDED CORROSION ON THE RT PRESSURE FLOOR SILL ASSY APPROX RBL 36.00 - RBL 45.00 AND BETWEEN FS409.00 +128 AND FS559.00 IAW SRM 51-21-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE ACCEPTABLE PER AND COMPLIED WITH REO 601R-53-41-666 REV "-C" DATED 2012-11-06. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY.