What was found
AFT SIDE OF AFT PRESSURE BULKHEAD ZEE MEMBER ANGLE AT STR 15L, LBL 36.20 CRACKED. RECEIVED, LOCATED AND DRILLED A NEW INTERCOSTAL IAW SRM 51-42-06. INSTALLED THE NEW INTERCOSTAL IAW DWG 601-35012, REV D, AND SRM 51-42-06. COMPLIED WITH TASK CARD 51-900-1003-SKY.