As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE RA18382-601R-57-21-1703-PR. COMPLY WITH PERMANENT REPAIR ON RA ID 183824 . FASTNER HOLES IN LT MLG TRUNNION ARE CRACKED. REPAIRED IAW REO 601R-57-21-1703, REV -. REPLACED THE LT TRUNNION MLG AND STEEL STRAP POST SB 601R-57-046, REV-A.