What was found
FS280.00 FLOORBEAM TO LBL 9 FLOOR BEAM, THE THE AFT SIDE OUTBD ATTACH ANGLE IS CRACKED. REMOVED AND REPLACED CRACKED OTBD ATTACH ANGLE ON THE AFT SIDE OF LBL 9.0 AT BS 280 WITH NEW ANGLE (P/N CC670-34099-1SB) USING ALL NEW FASTENERS, REF SRM 51-42-21-001-001-A01 AND DWG CC670-34010 REV K SEE CONTINUATION STEPS FOR MORE DETAILS. SKYCARD 51-900-1002-SKY COMPLIED WITH IN ITS ENTIRETY.