As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BS 280 FLOORBEAM TO RBL 9 FLOORBEAM, THE THE AFT SIDE OUTBD ATTACH ANGLE IS CRACKED. REMOVED AND REPLACED CRACKED OUTBD ATTACH ANGLE ON THE AFT SIDE OF RBL 9.0 AT BS280 WITH NEW ANGLE USING ALL NEW FASTENERS IAW SRM 51-42-21-001-001-A01 AND DWG CC670-34010 REV-K.