What was found
DURING INSTALLATION OF FRAME SPLICE AT RT BS 379 FOUND REINFORCEMENT ANGLE SPLICE WITH ELONGATED HOLES. REPLACED REINFORCEMENT ANGLE SPLICE IAW SRM 51-42-06-001-001-A01, REV 38, AND DWG SH670-31401, REV A. COMPLIED WITH TASK CARD 51-900-1002-SKY.