What was found
ACCORDING WITH NDT INSPECTION WO 14350-3816, THE WINDSHIELD CENTER POST AND BULKHEAD AFT POST AT FS 20275 - 2 CRACKS NOTED. REMOVED AND REPLACED WINDSHIELD CENTER POST AND BULKHEAD AFT POST AT FS 20275 FITTING PN 601R33237-2S PO2319 AND STRAP PN 601R34012-25 PO2319 INTERNAL STRUCTURE IAW CRJ200 SRM 51-42-21 SRM 53-11-35 SRM 53-11-19