What was found
SERVICE DOOR LOWER SILL FLOOR SUPPORT ANGLE HAS ELONGATED MOUNT SCREW HOLES AND SPOTS OF CORROSION. REMOVED THE DAMAGE ANGLE AND INSTALLED A NEW SUPPORT ANGLE IAW SRM 51-42-11, AND DWG 601R38303, REV AR. COMPLIED WITH 51-900-1003-SKY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR LOWER SILL FLOOR SUPPORT ANGLE HAS ELONGATED MOUNT SCREW HOLES AND SPOTS OF CORROSION. REMOVED THE DAMAGE ANGLE AND INSTALLED A NEW SUPPORT ANGLE IAW SRM 51-42-11, AND DWG 601R38303, REV AR. COMPLIED WITH 51-900-1003-SKY.