As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT FLOOR SUPPORT LBL 9, BS 379 - 409.112 CORRODED IN SEVERAL LOCATIONS. REMOVED CORROSION FROM FLOOR SUPPORT FLANGE AT LBL9 OTBD SIDE BS 409.96 IAW SRM 51-21-06 FOUND OUT OF LIMITS WIT A 100 MATERIAL LOSS REF SRM 53-00-00-01 PERFORMED A REPAIR WITH INSTALLATION OF REPAIR PARTS FOR FLOOR SUPPORT FLANGE REPAIR AT APPROX BS 409.96, LBL 9 OTBD FLANGE IAW SRM 53-00-43-02 REPAIR 1.