SDR SWIA95714

Service difficulty report · Connector · Emb EMB120ER

Difficulty date
February 6, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N190SW
Make and model
Emb EMB120ER
Aircraft serial
120050
Engine
Pwa PW118A
Part
Connector
Condition
Miswired
Location
Rt Mlg
Stage of operation
TO
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT MAIN GEAR -A+ LIGHT DIDN'T EXTINGUISH AND NO OTHER GEAR LIGHTS WOULD ILLUMINATE WITH GEAR HANDLE DOWN. USED EMERGENCY GEAR EXTENSION PRECEDURE TO PUT GEAR DOWN. REPLACED RIGHT GEAR -A+ SYSTEM PROX WIRE HARNESS. AFTER CONNECTING PROX SENSOR, RIGHT RED -A+ LIGHT STAYS ON. TROUBLESHOT TO RIGHT UPLOCK CAM CANNON PLUG FOR PROX SENSOR WIRED INCORRECTLY. SWAPPED WIRES IN CANNON PLUG FOR -A+ SYSTEM AND -B+ SYSTEMS IN RIGHT WHEEL WELL FOR A LIGHT INDICATIONS. GROUND OPS CHECK GOOD.