SDR SWIA971744

Service difficulty report · Controller · Cndair CL6002B19

Difficulty date
March 30, 2000
Submitted
April 14, 2000
Operation
Air carrier
Aircraft
N408SW
Make and model
Cndair CL6002B19
Aircraft serial
7055
Aircraft time
14,289 hours, 12,764 cycles
Part
Controller
Condition
Failed
Location
Window Heat
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER LIFT OFF LEFT WINDOW HEAT MESSAGE CAME ON. RETURNED TO SLC. REMOVED AND REPLACED WINDSHIELD TEMPERATURE CONTROLLER (P/N 16591) (S/N 520) OFF, (S/N 418) ON, OPS CHECK GOOD IAW MM 304101. SW 301 AND 418 WERE SWAPPED FOR TROUBLESHOOTING WINDSHIELD CONTROLLER (S/N 418) WINDOW CONTROLLER OPERATIONAL CHECKS WERE GOOD.