FLT 6480 - DCA-LGA - GASPER FAN CIRCUIT BREAKER POPPED FOLLOWED BY BURNING SMELL FROM GASPER FAN VENTS. GASPER FAN SWITCH WAS PLACED TO OFF. REPLACED GASPER FAN IAW MM CHAPTER 21-23-1. OPERATIONAL CHECK NORMAL. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 6480 - DCA-LGA - GASPER FAN CIRCUIT BREAKER POPPED FOLLOWED BY BURNING SMELL FROM GASPER FAN VENTS. GASPER FAN SWITCH WAS PLACED TO OFF. REPLACED GASPER FAN IAW MM CHAPTER 21-23-1. OPERATIONAL CHECK NORMAL. (M)