What was found
WITH BOTH PUMPS OFF (BYPASS) HYDRAULIC SYSTEM PRESSURE REMAINED AT 3,000 PSI. WHEN NR 2 ENGINE WAS SHUT DOWN NR 3 ENGINE BYPASS FUNCTION OPERATES NORMALLY AND NUMBER 2 BYPASS IS NOT OPERATING. REPAIRED WIRING AT CANNON PLUG NR 2 ENGINE BYPASS. OPS CHECK NR 2 AND NR 3 ENGINE BYPASS, ALL CHECK OK PER MM 29-10.