SDR TC8A97017

Service difficulty report · Wire · Doug DC8F55

Difficulty date
March 8, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N182SK
Make and model
Doug DC8F55
Aircraft serial
45817
Part
Wire
Condition
Broken
Location
Nr 2 Eng Bypass
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WITH BOTH PUMPS OFF (BYPASS) HYDRAULIC SYSTEM PRESSURE REMAINED AT 3,000 PSI. WHEN NR 2 ENGINE WAS SHUT DOWN NR 3 ENGINE BYPASS FUNCTION OPERATES NORMALLY AND NUMBER 2 BYPASS IS NOT OPERATING. REPAIRED WIRING AT CANNON PLUG NR 2 ENGINE BYPASS. OPS CHECK NR 2 AND NR 3 ENGINE BYPASS, ALL CHECK OK PER MM 29-10.