What was found
CORROSION ON FLOOR SUPPORT ANGLE ON ASD SILL. REMOVED FWD, MID, AFT ANGLE, LOWER ASD ANGLE AND FWD AND AFT STAIR RAIL FITTINGS. DRILLED, COUNTERSANK, DEBURRED AND ALODINED NEW MID CAP ANGLE PER CRJ 700 SRM 51-42-06. DRILLED, DEBURRED AND COUNTERSANK NEW KICKPLATE PER CRJ 700 SRM 51-40-00. FINISHED INSTALLING NEW KICKPLATE, INSTALLED NEW MID CAP ANGLE AND FWD AND AFT STAIR RAIL FITTINGS AND SEALED AND RESTORED FINISH TO REPAIR AREA PER CRJ 700 SRM 51-42-03, 51-23-00 AND 51-25-16.