What was found
FRAME CORRODED AT FS 333 STRINGER 27. REMOVED FASTNERS AND BLENDED CORRISION IAW CRJ 700 SRM 51-42-06. PERFORMED THICKNESS MEASUREMENT OF BLEND AREA AT FS 333, STR 27 IAW CRJ 700 NDTM 51-20-004. MINIMUM THICKNESS IS .047". SUBMITTED AND RECIEVED REO 670-53-21-260 FOR FS 333 AT STR27. BLENDOUT IS WITHIN LIMITS OF REO 670-53-21-260 ITEM 12. PERFORMED EDDY CURRENT INSPECTION OF BLEND AREA AT FS 333, STR. 27 IAW REO 670-53-21-260 PER CRJ 700 NDTM 51-20-006. NO DEFECTS NOTED. INSTALLED NEW FASTENERS WHERE THEY WERE REMOVED FOR CORROSION REMOVAL IAW CRJ 700 SRM 51-42-06. TREATED, PRIMED AND PAINTED SKIN WHERE RIVETS WERE REMOVED IAW CRJ 700 SRM 51-26-01. JOB COMPLETE.