As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT I/B SLAT CLOSING PLATE AND INTERCOSTAL CRACKED. LOCATED NEW SERVICEABLE INTERCOASTAL AND INSTALLED WITH SOLID FASTENERS TO SERVICEABLE CLOSING PLATE IAW CRJ 700 SRM 51-42-06. TRIMMED SERVICEABLE CLOSING PLATE TO FIT. OKAY TO PAINT. PRIME AND PAINTED, IAW CRJ SRM 51-25-16. REQUIRES INSTALLATION; CLEARANCE FIT, TO COMPLETE. INSTALLED RT TELESCOPIC DUCT CLOSING PLATE IAW CRJ 700 AMM 27-81-00. CLEARENCE AND FIT CHECK GOOD.