What was found
FOUND EXFOLIATION CORROSION ON INTERNAL STRUCTURE OF LT OUTBOARD FLAP ASSY IAW TASKCARD 000-57-590-502. REMOVED AND REPLACED LT OUTBOARD FLAP PANEL IAW CRJ 700 AMM 27-52-29. RIG AND OP'S CHECK GOOD IAW CRJ 700 AMM 27-52-00. STARTED REMOVING FLAP FAIRING PANEL BRACKETS FROM OLD FLAP ASSY AND REINSTALLING ON NEW LT FLAP ASSY AS REQUIRED PER CRJ 700 SRM 51-42-00. COMPLETED REMOVAL AND TRANSFER OF FLAP FAIRING BRACKETS IAW CRJ 700 SRM 51-42-00. 06/27/2007 JOB COMPLETE. C/W RII IAW SP 607 AND CRJ 700 AMM 27-52-00. SUPPLEMENTAL - SDR CLOSED 06/29/07.