As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING OP 16 MAINT CHECK AT STA 1307 BETWEEN STRINGER 39R AND 38R, FOOT ON FLOORBEAM HAD CORROSION. REPLACED CORRODED FORMER FOOT WITH STOCK MATERIAL. PROTECTIVE TREATED NEW FORMER FOOT PER SRM 51-20-01 TABLE 1 SHEET 1 PAGE 1. SEALED PARTS FOR INSTALLATION PER SRM 51-20-00. SUBSTITUTED BACB30 HI-LOKS PER SRM 51-40-03 PAGE 2 SHEET 14. INSTALLED FASTENERS PER SRM 51-40-02.