What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION ON AFT CARGO FLOORBEAM CAP AT STA 1395, STRINGER 33L. REMOVED CORRODED FLOORBEAM CAP AND INSTALLED NEW SECTION FROM LBL 34 IN TO 46 IN AT STA 1395, PER SRM 53-60-51, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION ON AFT CARGO FLOORBEAM CAP AT STA 1395, STRINGER 33L. REMOVED CORRODED FLOORBEAM CAP AND INSTALLED NEW SECTION FROM LBL 34 IN TO 46 IN AT STA 1395, PER SRM 53-60-51, AND SRM 51-40-02.