What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION ON CABIN FLOORBEAM AT STA 287, LBL 36 IN TO RBL 80 IN. REMOVED CORRODED FLOORBEAM AND REPLACED FLOORBEAM T CAP AT STA 287, LBL 36 IN TO RBL 80 PER SRM 53-00-51, PAGE 201 TO 205.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION ON CABIN FLOORBEAM AT STA 287, LBL 36 IN TO RBL 80 IN. REMOVED CORRODED FLOORBEAM AND REPLACED FLOORBEAM T CAP AT STA 287, LBL 36 IN TO RBL 80 PER SRM 53-00-51, PAGE 201 TO 205.