What was found
DURING CHECK-C MAINT, FOUND NR 6 LEADING EDGE SLAT, O/B SIDE REPAIR DELAMINATED. REPLACED CORRODED HONEYCOMB AND INSTALLED 12.5 IN BY 13 IN METAL OVERLAY PER SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, FOUND NR 6 LEADING EDGE SLAT, O/B SIDE REPAIR DELAMINATED. REPLACED CORRODED HONEYCOMB AND INSTALLED 12.5 IN BY 13 IN METAL OVERLAY PER SRM 51-70-10.