What was found
DURING INSPECTION IAW TASK CARD 53-852-01-01 FOUND AFT CARGO DOORWAY CEILING PANEL SUPPORT AT STATION 1900 RT OF BL 84 CRACKED. CRACK LENGTH .7 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION IAW TASK CARD 53-852-01-01 FOUND AFT CARGO DOORWAY CEILING PANEL SUPPORT AT STATION 1900 RT OF BL 84 CRACKED. CRACK LENGTH .7 INCHES.