What was found
DUCT PRESS DROPS WHEN USING APU BLEED AIR FOR ENGINE START OR PACK OPERATION. DUCT PRESSURE DROPS TO. DUCT PRESS DROPS 11-15 PSI DURING ENGINE START. NO LOAD DUCT PRESS 25 PSI. REPLACED SURGE VALVE & BLEED VALVE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DUCT PRESS DROPS WHEN USING APU BLEED AIR FOR ENGINE START OR PACK OPERATION. DUCT PRESSURE DROPS TO. DUCT PRESS DROPS 11-15 PSI DURING ENGINE START. NO LOAD DUCT PRESS 25 PSI. REPLACED SURGE VALVE & BLEED VALVE.