What was found
ONE SPAR VALVE LIGHT REMAINED ILLUMINATED WITH FUEL CONTROL SWITCH SELECTED (CUTOFF, RICH, RUN). EICAS MSG (L, R) SPAR VALVE DISPLAYED. REPLACED ENG FUEL SHUTOFF VALVE & OPS CHECKS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ONE SPAR VALVE LIGHT REMAINED ILLUMINATED WITH FUEL CONTROL SWITCH SELECTED (CUTOFF, RICH, RUN). EICAS MSG (L, R) SPAR VALVE DISPLAYED. REPLACED ENG FUEL SHUTOFF VALVE & OPS CHECKS NORMAL.