As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ADP LT FUSELAGE DRIPPING HYD FLUID FROM PLUG ON RT SIDE OF PUMP. PLUG ON RT SIDE IS A BREATHER PLUG AND DRIPS APPROX 5 DROPS PER MINUTE. COMPONENT VENT HOLES DISPATCH LIMIT 30 DROPS PER MIN OR LESS. PUMP TO BE REPAIRED OR REPLACED WITHIN 75 FLIGHT HOURS. FIVE DROPS PER MIN IS STATIC. NO LEAKS WHILE OPERATING. REPLACED CTR ADP PER AMM. PERFORMED SUCCESSFUL OPS CHECK AND LEAK CHECK PER AMM.