What was found
FQTY RT MAIN DISPLAY BLANK. RELAY RT CTR FUEL PUMP INHIBIT IN P210 IS NOT IN COMMANDED POSITION. ACTIVE MESSAGE 28-12017. DID STEPS A&B FIM 28-22 TASK 839, NO HELP. REPLACED RH #17 TANK UNIT, AND LH #14, BITE CHK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FQTY RT MAIN DISPLAY BLANK. RELAY RT CTR FUEL PUMP INHIBIT IN P210 IS NOT IN COMMANDED POSITION. ACTIVE MESSAGE 28-12017. DID STEPS A&B FIM 28-22 TASK 839, NO HELP. REPLACED RH #17 TANK UNIT, AND LH #14, BITE CHK GOOD.