As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLEED LOOP 2 STRUT L DETECTOR FAULT. FOUND INTERMITTENT SHORT TO GROUND ON WIRE W4519-2009R-20 AT LWR FWD INBD CORNER OF P105 PANEL. REPAIRED INSULATION IAW SWPM, REPOSITIONED AND SECURED HARNESS. ALSO FOUND LOW RESISTANCE TO GRD ON CONNECTOR DM26104A. NEEDS NEW CONN. WIRING REPAIRED IAW 20-10-13. CLEANED CONNECTOR AND REINSTALLED. OPS CHECKED GOOD. SHOOK WIRING, ALL CHECKED GOOD.