What was found
NR 2 ENGINE FOUND MOST HPC STAGE 13 & 15 BLADES WITH L/E IMPACT DAMAGE EXCEEDING LIMITS. EXCEED LIMITS IN AREAS 'A','B','C' AND 'E' THAT ARE ALLOWED. REQUIRES ENG CHANGE. REMOVED NR 2 ENG. THIS IS PRECAUTIONARY DUE TO ECM PARAMETER SHIFT. IF CAN CONTINUE IN SERVICE AT REDUCED INSPECT INTERVAL, UPDATE CALLOUT EC4001 AND-OR EC4011 WITH INTERVAL AND FINDINGS. IF HPT OK, BORESCOPE HPC COMPRESSOR BLADES STG 5, 6, 7, 9, 11, 13. IF IN LIMITS BUT EVIDENCE OF IMPACT, BORO ALL STAGES HPC. DMG LESS THAN ABOUT 0.1 INCH DEEP MAY BE ON-WING BLENDABLE, CONTACT SFOPI FOR RPR 72-00-00 RU06. FOUND HPT BLADE AND HPC 13 AND 15 WITH DAMAGE THAT EXCEED THE MM LIMITS. PER OPBLM. NO NEED TO CONTINUE WITH THE REST OF THE COMPRESSOR BORESCOPE. ENG CHANGE REQUIRED.