What was found
L WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. -ANTI-ICE. ON PFR FAULTING SENSOR, NEEDS MORE TIME FOR T-S. INSTALLED JUMPER HARNESS TO USE NR 2 SENSOR AND REPLACED WINDOW HEAT CONTROLLER PRECAUTIONARY TESTS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L WINDSHIELD DISPLAYED ON UPPER ECAM SCREEN. -ANTI-ICE. ON PFR FAULTING SENSOR, NEEDS MORE TIME FOR T-S. INSTALLED JUMPER HARNESS TO USE NR 2 SENSOR AND REPLACED WINDOW HEAT CONTROLLER PRECAUTIONARY TESTS GOOD.