What was found
FWD ENTRY STA 324 FLOORBEAM CORROSION RBL 48-64. MAJOR REPAIR ACCOMPLISHED: AFTER CORROSION REMOVAL FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED T CHORD PER INSTRUCTIONS ON PD 57-53-127 &D UA EVA 80888 WITHOUT DEVIATION. ALSO CREATED CF9042 FOR DTA REQUIREMENT.