What was found
FWD ENTRY STA 365 RBL 60 FLOORBEAM CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION PER MM AND FOUND TO BE OUT OF LIMITS PER SRM. CUT OFF LBL 19 TO OUTBD RT, REPLACED UPPER FLOORBEAM CHORD PER SRM WITH BAC1505-100880. ALSO, REPLACED 2 ATTACH ANGLES AND 2 STRAPS. TREATED AND PRIMED PER AMM. INSTALLED ALL PARTS PER SRM.