What was found
PRESSURIZATION ISSUE, RTFL. SKIN AIR VALVE FAULT ON ECAM, RETURNED TO FIELD. CFDS SHOW SKIN AIR OUTLET VALVE 22HQ. DETERMINED AN INTERMITTENT FAULT WITH THE OUTFLOW VALVE. REPLACED SKIN AIR OUTFLOW VALVE IAW MM. BITE TESTED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.