What was found
AT 6500 FT LE DEVICES WOULD NOT EXTEND. RETRACTED FLAPS ELECTRICALLY. SELECTED ALTERNATE TO MOVE FLAPS WITH NO L/E MOVEMENT. REPLACED FSEU-2 PER MM, SYSTEM OPERATES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT 6500 FT LE DEVICES WOULD NOT EXTEND. RETRACTED FLAPS ELECTRICALLY. SELECTED ALTERNATE TO MOVE FLAPS WITH NO L/E MOVEMENT. REPLACED FSEU-2 PER MM, SYSTEM OPERATES.