What was found
NOSE LANDING GEAR DID NOT RETRACT ON FIRST ATTEMPT. SECOND ATTEMPT NORMAL. ASSOCIATED STANBY PITOT DISPLAYED ON ECAM. 25GAM SENSOR FAULTED ON CFDS. REPLACED SHORTED WIRES IN CONDUIT TO 25GA NLG SENSOR PER ESPM 20-33-11 AND AWM 32-21-03. ACCOMPLISHED OP CHECK PER MM 32-69-00 AND ACCOMPLISHED TEN SUCCESSFUL GEAR SWINGS, NO FAULTS FOUND REF NRE4355I.