What was found
ON CLIMB-OUT, GEAR WOULD NOT RETRACT, EXPERIENCED A LANDING GEAR SHOCK ABSORBER FAULT ECAM. FOUND 2 INPUT RODS SLIGHTLY BENT. REPLACED RODS. ADJUSTED SENSORS 25GA AND 24GA AND TARGETS FOR SENSORS REF MM 32-31-73. SWUNG NOSE GEAR SEVERAL TIMES, OPS CKS OK. NO MESSAGES.