What was found
DOOR 4R FWD LOWER EDGE BENT IN APPROX .075 IN DEPTH 1.5 IN WIDE APPROX 9 INCHES IN LENGTH LOCATED 10 INCHES BACK FROM FWD LOWER CORNER. PERFORMED EDDY CURRENT INSPECTION TO LOWER SKIN AND FASTENER HOLES THAT WERE REMOVED PER NTM PART 6 51-00-01 AND NTM PART 6 51-00-04. NO DEFECTS NOTED. REF ECRA 521002320, COMPLETED PART 1 UP TO AND INCLUDING STEP 6. REF EC-RA 5210-02320, ACP'D HFEC NO CRACKS FOUND. INSTALLED NEW FASTENERS.